TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
RESET Control
Pushbutton switch used to simulate reset function of stabilator control/auto
flight control panel. When pressed, test set 28 VDC STAB 2 POWER is sup-
plied through test set connector J1 and J2, to No. 1 and No. 2 stabilator ampli-
fiers, respectively. When pressed, test set NO. 1 and NO. 2 RESET indicators
go on. RESET control is OFF when not pressed.
MANUAL SLEW 1
Simulates No. 1 stabilator manual slew switch function of stabilator control/
Control
auto flight control panel. UP supplies test set 28 VDC STAB 1 POWER to
turn on NO. 1 SLEW UP indicator and also supplies power through test set
connector J1 to No. 1 stabilator amplifier. UP also supplies test set 28 VDC
STAB 1 POWER to turn on NO. 1 HOT slew indicator and also supplies
power through test set connector J1 to No. 1 stabilator amplifier. DN supplies
test set 28 VDC STAB 1 POWER to turn on NO. 1 SLEW DN indicator, and
also supplies power through test set connector J1 to No. 1 stabilator amplifier.
DN also supplies test set 28 VDC STAB 1 POWER to turn on NO. 1 HOT
SLEW indicator, and as well supplies power through test set connector J1 to
No. 1 stabilator amplifier. OFF disables simulation of No. 1 stabilator manual
slew switch function of stabilator control/auto flight control panel.
MANUAL SLEW 2
Simulates No. 2 stabilator manual slew function of stabilator control/auto flight
Control
control panel. UP supplies test set 28 VDC STAB 2 POWER to turn on NO. 2
SLEW UP indicator, and also supplies power through test set connector J2 to
No. 2 stabilator amplifier. UP also supplies test set 28 VDC STAB 2 POWER
to turn on NO. 2 HOT SLEW indicator, and as well supplies power through
test set connector J2 to No. 2 stabilator amplifier. DN supplies test set 28 VDC
STAB 2 POWER to turn on NO. 2 SLEW DN indicator, and also supplies
power through test set connector J2 to No. 2 stabilator amplifier. DN also sup-
plies test set 28 VDC STAB 2 POWER to turn on NO. 2 HOT SLEW indica-
tor, and as well supplies power through test set connector J2 to No. 2 stabilator
amplifier. OFF disables simulation of No. 2 stabilator manual slew switch
function of stabilator control/auto flight control panel.
FAULT MONITOR
NORM enables No. 1 stabilator fault monitor shutdown of automatic mode to
POSN 1 Control
function normally if No. 1 stabilator actuator position miscompare fault should
exist. INHIBIT supplies ground through test set connector J1 to No. 1 stabila-
tor amplifier, preventing shutdown of No. 1 stabilator automatic mode should
No. 1 stabilator actuator position miscompare fault exist.
FAULT MONITOR
NORM enables No. 2 stabilator fault monitor shutdown of automatic mode to
POSN 2 Control
function normally if No. 2 stabilator actuator position miscompare fault should
exist. INHIBIT supplies ground through test set connector J2 to No. 2 stabila-
tor amplifier, preventing shutdown of No. 2 stabilator automatic mode, should
No. 2 stabilator actuator position miscompare fault exist.
FAULT MONITOR I
NORM enables No. 1 stabilator amplifier current limit fault monitor circuit to
LIMIT 1 Control
function normally if a current sense fault exists. INHIBIT supplies ground
through test set connector J1 to No. 1 stabilator amplifier, preventing shutdown
of No. 1 stabilator automatic mode, should a current sense fault exist.