TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
NOSE DN/NOSE UP
Supplies variable dc simulation signal through selected SIM position of mode
Control
selector control, to specific amplifiers selected. Simulation voltages, which are
selected by mode selector control and supplied through test set connector J1 to
No. 1 stabilator amplifier, can be monitored at STAB 1 SIM test point. Simu-
lation voltages, which are selected by mode selector control and supplied
through test set connector J2 to No. 2 stabilator amplifier, can be monitored at
STAB 2 SIM test point. Simulation voltages, which are selected by mode
selector control and supplied through test set connector J3 to SAS amplifier,
can be monitored at SAS SIM test point. Simulation voltages supplied to No. 1
and No. 2 stabilator amplifiers are within voltage range of -5.0 vdc to 5.0 vdc.
From 0 vdc reference, turning control NOSE DN supplies positive voltage out-
put from test set to No. 1 and No. 2 stabilator amplifiers and turning control
NOSE UP supplies negative voltage output from test set to No. 1 and No. 2
stabilator amplifiers. Simulation voltages supplied to SAS amplifiers are within
voltage range of -1.0 vdc to 1.0 vdc. From 0 vdc reference, turning control
NOSE DN supplies negative voltage output from test set to SAS amplifier, and
turning control NOSE UP supplies positive voltage output from test set to SAS
amplifier.