Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
STAB 1 SIM Test Point
Provides monitoring capability for No. 1 lateral accelerometer simulation sig-
nal when mode selector control is at SIM STAB 1 & 2 or SIM STAB 1. Pro-
vides monitoring capability for ground supplied to No. 1 stabilator amplifier
when mode selector control is at GND or SIM SAS 1. When mode selector
control is at NORM or SIM STAB 2, STAB 1 SIM test point is connected to
STAB 1 SNSR test point to provide monitoring capability for signal output
from No. 1 lateral accelerometer.
STAB 2 SNSR Test Point
Provides monitoring capability for signal output of No. 2 lateral accelerometer.
When mode selector control is at NORM or SIM STAB 1, STAB 2 SNSR test
point is connected to STAB 2 SIM test point.
STAB 2 SIM Test Point
Provides monitoring capability for No. 2 lateral accelerometer simulation sig-
nal when mode selector control is at SIM STAB 1 & 2 or SIM STAB 2. Pro-
vides monitoring capability for ground supplied to No. 2 stabilator amplifier
when mode selector control is at GND or SIM SAS 1. When mode selector
control is at NORM or SIM STAB 1, STAB 2 SIM test point is connected to
STAB 2 SNSR test point to provide monitoring capability for signal output
from No. 2 lateral accelerometer.
SAS SNSR Test Point
Provides monitoring capability for filtered lateral accelerometer output signal
from No. 1 stabilator amplifier. When mode selector control is at NORM or
SIM STAB 1, SAS SNSR test point is connected to SAS SIM test point.
SAS SIM Test Point
Provides monitoring capability for filtered lateral accelerometer simulation sig-
nal when mode selector control is at SIM SAS 1. Provides monitoring capabil-
ity for ground supplied to SAS amplifier when mode selector control is at
GND, SIM STAB 1 & 2, and SIM STAB 2. When mode selector control is at
NORM or SIM STAB 1, SAS SIM test point is connected to SAS SNSR test
point to provide monitoring capability for filtered lateral accelerometer output
signal from No. 1 stabilator amplifier.
L/R Control
Supplies variable dc simulation signal through selected SIM position of mode
selector control to specific amplifiers selected. Simulation voltages, which are
selected by mode selector control and supplied through test set connector J1 to
No. 1 stabilator amplifier, can be monitored at STAB 1 SIM test point. Simu-
lation voltages, which are selected by mode selector control and supplied
through test set connector J2 to No. 2 stabilator amplifier, can be monitored at
STAB 2 SIM test point. Simulation voltages, which are selected by mode
selector control and supplied through test set connector J3 to SAS amplifier,
can be monitored at SAS SIM test point. Simulation voltages supplied to No. 1
and No. 2 stabilator amplifiers are within voltage range of -3.75 vdc to 3.75
vdc. From 0 vdc reference, turning control L supplies positive voltage output
from test set to No. 1 and No. 2 stabilator amplifiers, and turning control R
supplies negative voltage output from test set to No. 1 and No. 2 stabilator
amplifiers. Simulation voltages supplied to SAS amplifier are within voltage
range of -3.0 vdc to 3.0 vdc. From 0 vdc reference, turning control L supplies
negative voltage output from test set to SAS amplifier and turning control R
supplies positive voltage output from test set to SAS amplifier.