TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
Mode Selector Control
NORM supplies No. 1 and No. 2 stabilator actuator feedback signals through
test set connectors J1 and J2, to No. 1 and No. 2 stabilator amplifiers, respec-
tively. This position also allows No. 1 and No. 2 stabilator amplifiers to moni-
tor position and rate of movement of No. 2 and No. 1 stabilator actuators,
respectively. Signals from No. 1 stabilator actuator can be monitored at NO. 1
SNSR and NO. 1 SIM test points. Signals from No. 2 stabilator actuator can
be monitored at NO. 2 SNSR and NO. 2 SIM test points. GND supplies
ground from test set through connectors J1 and J2, to No. 1 and No. 2 stabila-
tor amplifiers. These grounds can be monitored at NO. 1 and NO. 2 SIM test
points. SIM STAB 1 & 2 supplies variable dc simulation signal selected by
DN/UP control through test set connectors J1 and J2, to No. 1 and No. 2 stabi-
lator amplifiers, respectively. This position also supplies No. 1 simulation sig-
nal through test set connector J2 to No. 2 stabilator amplifier and No. 2 simu-
lation signal through test set connector J1 to No. 1 stabilator amplifier. These
simulation signals can be monitored at NO. 1 and NO. 2 SIM test points. SIM
STAB 1 supplies variable dc simulation signal selected by DN/UP control
through test set connector J1 to No. 1 stabilator amplifier. Variable dc simula-
tion signal is also supplied through test set connector J2 to No. 2 stabilator
amplifier for monitoring simulated No. 1 stabilator actuator position. This
simulation signal can be monitored at NO. 1 SIM test point. This switch posi-
tion also supplies ground through test set connector J2 to No. 2 stabilator
amplifier. Ground is also supplied through test set connector J1 to No. 1 stabi-
lator amplifier. This ground can be monitored at NO. 2 SIM test point. SIM
STAB 2 supplies variable dc simulation signal selected by DN/UP control
through test set connector J2 to No. 2 stabilator amplifier. Variable dc simula-
tion signal is also supplied through test set connector J1 to No. 1 stabilator
amplifier for monitoring simulated No. 2 stabilator actuator position. This
simulation signal can be monitored at NO. 2 SIM test point. This switch posi-
tion also supplies ground through test set connector J1 to No. 1 stabilator
amplifier. Ground is also supplied through test set connector J2 to No. 2 stabi-
lator amplifier. This ground can be monitored at NO. 1 SIM test point.
LATL ACCLRM
Provides capability for simulating or monitoring signal output of No. 1 and/or
Simulator
No. 2 lateral accelerometers. Used for testing acceleration functions of No. 1
and No. 2 stabilator amplifiers. Also provides capability for simulating or
monitoring filtered lateral accelerometer signal from No. 1 stabilator amplifier.
This is used for testing acceleration functions of stability augmentation system
(SAS) amplifier.
STAB 1 SNSR Test Point
Provides monitoring capability for signal output of No. 1 lateral accelerometer.
When mode selector control is at NORM or SIM STAB 2, STAB 1 SNSR test
point is connected to STAB 1 SIM test point.
2-15
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |