Page Title: Table 2-1. Operator's Controls. (cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
ACTR POSN Simulator
Provides capability for simulating or monitoring No. 1 and/or No. 2 stabilator
actuator position feedback signals. Used for testing function of No. 1 and No.
2 stabilator amplifiers.
NO. 1 SNSR Test Point
Provides monitoring capability for No. 1 stabilator actuator position feedback
signal. When mode selector control is at NORM, NO. 1 SNSR test point is
connected to NO. 1 SIM test point.
NO. 1 SIM Test Point
Provides monitoring capability for No. 1 stabilator actuator position feedback
simulation signal when mode selector control is at SIM STAB 1 & 2 or SIM
STAB 1. Provides monitoring capability for ground supplied to No. 1 stabilator
amplifier when mode selector control is at GND or SIM STAB 2. When mode
selector control is at NORM, NO. 1 SIM test point is connected to NO. 1
SNSR test point to provide monitoring capability for position feedback signal
from No. 1 stabilator actuator. All signals monitored at NO. 1 SIM test point
are also supplied through test set connector J2 to No. 2 stabilator amplifier for
monitoring No. 1 stabilator actuator position and rate of movement.
NO. 2 SNSR Test Point
Provides monitoring capability for No. 2 stabilator actuator position feedback
signal. When mode selector control is at NORM, NO. 2 SNSR test point is
connected to NO. 2 SIM test point.
NO. 2 SIM Test Point
Provides monitoring capability for No. 2 stabilator actuator position feedback
simulation signal when mode selector control is at SIM STAB 1 & 2 or SIM
STAB 2. Provides monitoring capability for ground supplied to No. 2 stabilator
amplifier when mode selector control is at GND or SIM STAB 1. When mode
selector control is at NORM, NO. 2 SIM test point is connected to NO. 2
SNSR test point to provide monitoring capability for position feedback signal
from No. 2 simulator actuator. All signals monitored at NO. 2 SIM test point
are also supplied through test set connector J1 to No. 1 stabilator amplifier for
monitoring No. 2 stabilator actuator position and rate of movement.
DN/UP Control
Supplies variable dc simulation signal, with voltage range of -15.0 vdc to 15.0
vdc, through selected SIM position of mode selector control to specific ampli-
fiers selected. Simulation voltages, which are selected by mode selector control
and supplied through test set connector J1 to No. 1 stabilator amplifier, can be
monitored at NO. 1 SIM test point. Simulation voltages, which are selected by
mode selector control and supplied through test set connector J2 to No. 2 sta-
bilator amplifier, can be monitored at NO. 2 SIM test point. From 0 vdc refer-
ence, turning control DN supplies positive voltage output from test set and
turning control UP supplies negative voltage output from test set. Control can
be turned 10 complete turns from each mechanical stop.