Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
NO. 2 SNSR Test Point
Provides monitoring capability for signal output of No. 2 airspeed sensor.
When mode selector control is at NORM, NO. 1 SNSR test point is connected
to NO. 1 SIM test point.
NO. 2 SIM Test Point
Provides monitoring capability for No. 2 airspeed sensor simulation signal
when mode selector control is at SIM STAB 1 & 2 or SIM STAB 2. Provides
monitoring capability for 2.26 vdc (simulated signal output from airspeed sen-
sor from 0 to 30 knots of airspeed) supplied to No. 2 stabilator amplifier when
mode selector control is at SIM STAB 1. When mode selector control is at
NORM, NO. 1 SIM test point is connected to NO. 1 SNSR test point to pro-
vide monitoring capability for signal output of No. 2 airspeed sensor.
DECR/INCR Control
Supplies variable dc simulation signal, with voltage range of less than 2.0 vdc
and not greater than 15.0 vdc, through selected SIM of mode selector control,
to specific amplifiers selected. Simulation voltages, which are selected by mode
selector control and supplied through test set connector J1 to No. 1 stabilator
amplifier, can be monitored at NO. 1 SIM test point. Simulation voltages,
which are selected by mode selector control and supplied through test set con-
nector J2 to No. 2 stabilator amplifier, can be monitored at NO. 2 SIM test
point. Turning control in INCR direction increases positive voltage output from
test set. Turning control in DECR direction decreases positive voltage output
from test set. Test set variable dc signal output is equal to 75 millivolts per
knot of simulated airspeed.
Mode Selector Control
NORM position supplies output from No. 1 and No. 2 airspeed sensors
through test set connectors J1 and J2, to No. 1 and No. 2 stabilator amplifiers,
respectively. Signals from No. 1 airspeed sensor can be monitored at NO. 1
SNSR and NO. 1 SIM test points. Signals from No. 2 airspeed sensor can be
monitored at NO. 2 SNSR and NO. 2 SIM test points. OFF position opens
input to stabilator amplifier to test amplifier's auto shutdown function. SIM
STAB 1 & 2 supplies variable dc simulation signal selected by DECR/INCR
control through test set connectors J1 and J2, to No. 1 and No. 2 stabilator
amplifiers, respectively. These simulation signals can be monitored at NO. 1
and NO. 2 SIM test points. SIM STAB 1 supplies variable dc simulation signal
selected by DECR/INCR control through test set connector J1, to No. 1 stabi-
lator amplifier. This simulation signal can be monitored at NO. 1 SIM test
point. This switch position also supplies 2.26 vdc (simulated signal output
from airspeed sensor from 0 to 30 knots of airspeed) through test connector J2,
to No. 2 stabilator amplifier. This 2.26 vdc can be monitored at NO. 2 SIM
test point. SIM STAB 2 supplies variable dc simulation signal selected by
DECR/INCR control through test set connector J2, to No. 2 stabilator ampli-
fier. This simulation signal can be monitored at NO. 2 SIM test point. This
switch position also supplies 2.26 vdc (simulated signal output from airspeed
sensor from 0 to 30 knots of airspeed), through test set connector J1, to No. 1
stabilator amplifier. This 2.26 vdc can be monitored at NO. 1 SIM test point.