Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
DN/UP Control
Supplies variable dc simulation signal, with a voltage range of -6.6 vdc to 6.6
vdc, through selected SIM of mode selector control, to specific amplifiers
selected. Simulation voltages, which are selected by mode selector control and
supplied through test set connector J1 to No. 1 stabilator amplifier, can be
monitored at NO. 1 SIM test point. Simulation voltages, which are selected by
mode selector control and supplied through test set connector J2 to No. 2 sta-
bilator amplifier, can be monitored at NO. 2 SIM test point. From 0 vdc refer-
ence, turning control DN supplies positive voltage output from test set, and
turning control UP supplies negative voltage output from test set.
Mode Selector Control
NORM supplies output signal from No. 1 and No. 2 collective stick position
sensors through test set connectors J1 and J2, to No. 1 and No. 2 stabilator
amplifiers, respectively. Signals from No. 1 collective stick position sensor can
be monitored at NO. 1 SNSR and NO. 1 SIM test points. Signals from No. 2
collective stick position sensor can be monitored at NO. 2 SNSR and NO. 2
SIM test points. GND supplies ground from test set through connectors J1 and
J2, to No. 1 and No. 2 stabilator amplifiers, respectively. These grounds can be
monitored by NO. 1 and NO. 2 SIM test points. SIM STAB 1 & 2 position
supplies variable dc simulation signal selected by DN/UP control through test
set connectors J1 and J2, to No. 1 and No. 2 stabilator amplifiers, respectively.
These simulation signals can be monitored at NO. 1 and NO. 2 SIM test
points. SIM STAB 1 supplies variable dc simulation signal selected by DN/UP
control through test set connector J1 to No. 1 stabilator amplifier. This simula-
tion signal can be monitored at NO. 1 SIM test point. This switch position also
supplies ground through test set connector J2 to No. 2 stabilator amplifier. This
ground can be monitored at NO. 2 SIM test point. SIM STAB 2 supplies vari-
able dc simulation signal selected by DN/UP control through test set connector
J2 to No. 2 stabilator amplifier. This simulation signal can be monitored at
NO. 2 SIM test point. This switch position also supplies ground through test
set connector J1 to No. 1 stabilator amplifier. This ground can be monitored at
NO. 1 SIM test point.
AS SENSOR Simulator
Provides capability for simulating or monitoring signal output from NO. 1
and/or NO. 2 airspeed sensors. Used for testing airspeed functions of No. 1
and No. 2 stabilator amplifiers.
NO. 1 SNSR Test Point
Provides monitoring capability for signal output of NO. 1 airspeed sensor.
When mode selector control is at NORM, NO. 1 SNSR test point is connected
to NO. 1 SIM test point.
NO. 1 SIM Test Point
Provides monitoring capability for No. 1 airspeed sensor simulation signal
when mode selector control is at SIM STAB 1 & 2 or SIM STAB 1. Provides
monitoring capability for 2.26 vdc (simulated signal output from airspeed sen-
sor from 0 to 30 knots of airspeed) supplied to No. 1 stabilator amplifier when
mode selector control is at SIM STAB 2. When mode selector control is at
NORM, NO. 1 SIM test point is connected to NO. 1 SNSR test point to pro-
vide monitoring capability for signal output of No. 1 airspeed sensor.