TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
NO. 2 Mode Select
NORM supplies output signal from scaling amplifier in No. 2 stabilator ampli-
Control
fier through test set connector J2 to driver logic module in No. 2 stabilator
amplifier. This signal can be monitored at NO. 2 SIM and NO. 2 SNSR test
points. GND supplies ground from test set through connector J2 to input of
driver logic module in No. 2 stabilator amplifier. This ground can be moni-
tored at NO. 2 SIM test points. SIM supplies variable dc simulator signal
selected by NO. 2 DN/UP control through test set connector J2 to driver logic
module in No. 2 stabilator amplifier. This signal can be monitored at NO. 2
SIM test point.
STAB 1 & 2/SINGLE
STAB 1 & 2 supplies variable dc simulation signal selected by NO. 1 DN/UP
Control
control through SIM of NO. 1 and NO. 2 mode selector controls and through
test set connectors J1 and J2 to driver logic module in No. 1 and No. 2 stabila-
tor amplifiers. This signal can be monitored at NO. 1 and NO. 2 SIM test
points. SINGLE supplies variable dc simulation signal selected by NO. 2
DN/UP control, through SIM of NO. 2 mode selector control, and through test
set connector J2 to driver logic module in No. 2 stabilator amplifier. This sig-
nal can be monitored at NO. 2 SIM test point.
CLTV STICK POSN
Provides capability for simulating or monitoring signal output from No. 1
Simulator
and/or No. 2 collective stick position sensors. Used for testing collective func-
tion of No. 1 and No. 2 stabilator amplifiers.
NO. 1 SNSR Test Point
Provides monitoring capability for signal output of No. 1 collective stick posi-
tion sensor. When mode selector control is at NORM, NO. 1 SNSR test point
is connected to NO. 1 SIM test point.
NO. 1 SIM Test Point
Provides monitoring capability for No. 1 collective stick position sensor simu-
lation signal when mode selector control is at SIM STAB 1 & 2 or SIM STAB
1. Provides monitoring capability for ground supplied to No. 1 stabilator
amplifier when mode selector control is at GND or SIM STAB 2. When mode
selector control is at NORM, NO. 1 SIM test point is connected to NO. 1
SNSR test point to provide monitoring capability for signal output of No. 1
collective stick position sensor.
NO. 2 SNSR Test Point
Provides monitoring capability for signal output of No. 2 collective stick posi-
tion sensor. When mode selector control is at NORM, NO. 2 SIM test point is
connected to NO. 2 SNSR test point.
NO. 2 SIM Test Point
Provides monitoring capability for No. 2 collective stick position sensor simu-
lation signal when mode selector control is at SIM STAB 1 & 2 or SIM STAB
2. Provides monitoring capability for ground supplied to No. 2 stabilator
amplifier when mode selector control is at GND or SIM STAB 1. When mode
selector is at NORM, NO. 2 SIM test point is connected to NO. 2 SNSR test
point to provide monitoring capability for signal output of No. 2 collective
stick position sensor.