TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
NO. 1 DN/UP Control
Supplies variable dc simulation signal, with a voltage range of -10.0 vdc to 0
to 10.0 vdc, through SIM of NO. 1 mode selector control and through test set
connector J1 to driver logic module in No. 1 stabilator amplifier. This simula-
tion voltage can be monitored at NO. 1 SIM test point. With STAB 1 &
2/SINGLE selector switch placed to STAB 1 & 2, this simulation signal is also
supplied through SIM of NO. 2 mode selector control and through connector
J2 to driver logic module in No. 2 stabilator amplifier, and can be monitored at
NO. 2 SIM test point. From 0 vdc reference, turning control DN supplies a
positive voltage output from test set, and turning control UP supplies a nega-
tive voltage output from test set. Control can be turned 10 complete turns from
each mechanical stop.
NO. 1 Mode Select
NORM position supplies output signal from scaling amplifier in No. 1 stabila-
Control
tor amplifier through test set connector J1 to driver logic module in No. 1 sta-
bilator amplifier. This signal can be monitored at NO. 1 SIM and NO. 1 SNSR
test points. GND position supplies ground from test set through connector J1
to input of driver logic module in No. 1 stabilator amplifier. This ground can
be monitored at NO. 1 SIM test point. SIM position supplies variable dc simu-
lation signal selected by NO. 1 DN/UP control, through test set connector J1,
to driver logic module in No. 1 stabilator amplifier. This signal can be moni-
tored at NO. 1 SIM test point.
NO. 2 SNSR Test Point
Provides monitoring capability for signal output from scaling amplifier in No.
2 stabilator amplifier. When NO. 2 mode selector control is at NORM, NO. 2
SIM test point is connected to NO. 2 SNSR test point.
NO. 2 SIM Test Point
Provides monitoring capability for SCALING AMPL simulator signal selected
by NO. 2 DN/UP control when NO. 2 mode selector control is at SIM. Pro-
vides monitoring capability for ground supplied to driver logic module in No.
2 stabilator amplifier when NO. 2 mode selector control is at GND. When NO.
2 mode selector control is at NORM, NO. 2 SNSR test point is connected to
NO. 2 SIM test point to provide monitoring capability for signal output from
scaling amplifier in No. 2 stabilator amplifier.
NO. 2 DN/UP Control
Supplies variable dc simulation signal, with voltage range of -10.0 vdc to 0 to
10.0 vdc, through SINGLE of STAB 1 & 2/SINGLE control, through SIM of
NO. 2 mode selector control, and through test set connector J2 to driver logic
module in No. 2 stabilator amplifier. This simulation voltage can be monitored
at NO. 2 SIM test point. From 0 vdc reference, turning control DN supplies
positive voltage output from test set and turning control UP supplies negative
voltage output from test set. Control can be turned 10 complete turns from
each mechanical stop.
2-10