Click here to make tpub.com your Home Page

Page Title: Table 2-1. Operator's Controls. (cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
PWR GND Test Point
Provides a ground reference point for monitoring power voltages. To minimize
undesirable effects of ground loops, power ground reference is received
through test set connector priority switching arrangements as follows:
Connectors Used
Power Excitation
Received From
J1, J2, J3
J1
J1 and J2
J1
J3
J3
SIG GND Test Point
Provides a ground reference point for monitoring signal voltages. Signal
ground reference is established at test set power supply and is made common
to power ground through helicopter wiring.
LAMP TEST
LAMP TEST Button
Provides test set lamps with press-to-test capability. When pressed, all STABI-
LATOR SYSTEM INDICATORS go on and SAS SYSTEM ENGAGE 1 and
2 indicators and AIRSPEED SWITCH 60 KNOTS indicator go on. 28 VDC
STAB 1 power is used to turn on STABILATOR SYSTEM INDICATORS
and 28 VDC SAS power is used to turn on SAS SYSTEM indicators.
STABILATOR SYSTEM
SCALING AMPL
Provides capability for simulating or monitoring signal output from No. 1
Simulator
and/or No. 2 stabilator amplifier - scaling amplifier. Used for testing No. 1 and
No. 2 stabilator amplifier - scaling amplifier commands for automatic mode
operation.
NO. 1 SNSR Test Point
Provides monitoring capability for signal output from scaling amplifier in No.
1 stabilator amplifier. When NO. 1 mode selector control is at NORM, NO. 1
SIM test point is connected to NO. 1 SNSR test point.
NO. 1 SIM Test Point
Provides monitoring capability for SCALING AMPL simulator signal selected
by NO. 1 DN/UP control when NO. 1 mode selector control is at SIM. Pro-
vides monitoring capability for ground supplied to driver logic module in No.
1 stabilator amplifier when NO. 1 mode selector control is at GND. When NO.
1 mode selector control is at NORM, NO. 1 SIM test point is connected to
NO. 1 SNSR test point to provide monitoring capability for signal output from
scaling amplifier in No. 1 stabilator amplifier.
2-9

Privacy Statement - Press Release - Copyright Information. - Contact Us