TM 1-6625-735-14
Table 2-1.
Operator's Controls. (Cont)
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
28 VDC SAS Indicator
Goes on to indicate 28 vdc power is applied to test set from helicopter ac elec-
trical power system, through helicopter circuit breaker, through test set connec-
tor J3, and through test set 28 VDC SAS circuit breaker.
28 VDC SAS Test Point
Provides monitoring capability for 28 vdc power that is used to turn on test set
28 VDC SAS indicator.
28 VDC SAS Circuit
Applies 28 vdc power to test set from helicopter dc electrical power system,
Breaker
through helicopter circuit breaker and through test set connector J3. Functions
as protective device during overloads and short circuits.
115 VAC 400 Hz STAB
Goes on to indicate 115 vac 400 Hz power is applied to test set from helicop-
1 Indicator
ter ac electrical power system, through helicopter circuit breaker, and through
test set connector J1.
115 VAC 400 Hz STAB
Provides monitoring capability for 115 vac 400 Hz power that is used to turn
1 Test Point
on test set 115 VAC 400 Hz STAB 1 indicator.
115 VAC 400 Hz STAB
Goes on to indicate 115 vac 400 Hz power is applied to test set from helicop-
2 Indicator
ter ac electrical power system, through helicopter circuit breaker, and through
test set connector J2.
115 VAC 400 Hz STAB
Provides monitoring capability for 115 vac 400 Hz power that is used to turn
2 Test Point
on test set 115 VAC 400 Hz STAB 2 indicator.
115 VAC 400 Hz SAS
Goes on to indicate 115 vac 400 Hz power is applied to test set from helicop-
Indicator
ter ac electrical power system, through helicopter circuit breaker, and through
test set connector J3.
115 VAC 400 Hz SAS
Provides monitoring capability for 115 vac 400 Hz power that is used to turn
Test Point
on test set 115 VAC 400 Hz SAS indicator.
+15 VDC and -15 VDC
Provide monitoring capabilities for 15 vdc and -15 vdc voltages which are
Test Points
supplied by power supply within test set. Power supply receives single-phase
115 vac 400 Hz excitation voltage through test set connector priority switching
arrangements as follows:
Connectors Used
Power Excitation
Received From
J1, J2, J3
J1
J1 and J2
J1
J3
J3
TEST SET Circuit
Applies single-phase 115 vac 400 Hz power to test set power supply from J1
Breaker
or J3 priority switching arrangements. Functions as protective device during
overloads and short circuits.