TM 1-6625-735-14
Operator's Controls.
CONTROL, INDICA-
TOR, TEST POINT, OR
CONNECTOR
FUNCTION
CONNECTORS
J1
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P405R
or MH-60K
heli-
EH-60A
UH-60Q
, and No. 1 stabilator amplifier through cable
copter connector P358R
assembly W2.
J2
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P404R
or MH-60K
heli-
EH-60A
UH-60Q
copter connector P358R
, and No. 1 stabilator amplifier through cable
assembly W6.
J3
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P423R
or MH-60K
heli-
EH-60A
UH-60Q
copter connector P286R
, and Stability Augmentation Set (SAS) amplifier
through cable assembly W1.
J4
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P428R
, and Stability Augmen-
EH-60A
UH-60Q
tation System/Flight Path Stabilization (SAS/FPS) computer connector J111
through cable assembly W4.
J5
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P422R
, and SAS/FPS computer connector
EH-60A
J121 through cable assembly W5.
J6
Provides electrical connection between test set, UH-60A
UH-60L
helicopter connector P421R
, and SAS/FPS computer connector
EH-60A
J139 through cable assembly W3.
POWER
28 VDC STAB 1
Goes on to indicate 28 vdc power is applied to test set from helicopter dc elec-
Indicator
trical power system through helicopter circuit breaker, through test set connec-
tor J1, and through test set 28 VDC STAB 1 circuit breaker.
28 VDC STAB 1 Test
Provides monitoring capability for 28 vdc power that is used to turn on test set
Point
28 VDC STAB 1 indicator.
28 VDC STAB 1 Circuit
Applies 28 vdc power to test set from helicopter dc electrical power system,
Breaker
through helicopter circuit breaker, and through test set connector J1. Functions
as protective device during overloads and short circuits.
28 VDC STAB 2
Goes on to indicate 28 vdc power is applied to test set from helicopter dc elec-
Indicator
trical power system through helicopter circuit breaker, through test set connec-
tor J2, and through test set 28 VDC STAB 2 circuit breaker.
28 VDC STAB 2 Test
Provides monitoring capability for 28 vdc power that is used to turn on test set
Point
28 VDC STAB 2 indicator.
28 VDC STAB 2 Circuit
Applies 28 vdc power to test set from helicopter dc electrical power system,
Breaker
through test set connector J2. Functions as protective device during overloads
and short circuits.
2-7
|