-16-
3-3 PERIODIC
MAINTENANCE
No special preventative maintenance such as lubrication, etc.
However,
is deemed necessary for this equipment.
a periodic check
or change of the hydraulic fluid and hydraulic filters should be
established.
The frequency of this check will depend on the
operating conditions that prevail a-t the location where the equip-
ment is being operated.
QUANTITY
HYDRAULIC - MECHANICAL
Filter Element
1
4
Adaptors (Actuator Test Ports)
2
Swivel Nut Run Tee
Swivel Nut Elbow
2
9 quarts
MIL-H-5606 Hydraulic Fluid
4
Hydraulic Hose
ELECTRICAL
1 box (5)
20 amp fuses
1 box (5)
4 amp fuses
28V lamps
2
5
800 mfd. capacitors
2
5K resistor (Voltmeter Shunt)
1
|