TM 9-4931-378-13&P
Table 2-1. Controls, Indicators and Connectors - Continued
Control, Indicator
Function
or Connector
Index No.
Enables CPU self test.
CPU TEST two position
5
toggle switch S2
Displays parity of all 64 bits of data.
PARITY FLR indicator DS9
6
Simulates LAI Fail discrete signal of EPU.
LAI FLR two-position
7
toggle switch S3
Simulates LAI Fail flag. Illuminates when LAI Fail
ADS FLR indicator DS10
8
signal is received from EPU.
Simulates Radar Altimeter Reliability signal
RDR ALT RELBL two-position
9
to EPU.
toggle switch S4
Illuminates when ADS NO GO signal is received
ADS NO GO indicator DS11
10
from EPU.
Enables power to indicators DS1 through DS12
SELF TEST two-position
11
for lamp check. DS12 is programmed to display 888.
toggle switch S5
OUTPUT SEL 2
12
14-position rotary switch
Specific Function
Sw Pos
S10
Selects the LAI + 15 Vdc output
LAI + 15V
of the EPU for monitoring.
Selects the LAI 15 Vdc output
LAI - 1 5 V
of the EPU for monitoring.
Selects the fore-aft TAS signal
VU
output of the EPU for monitoring.
Selects the lateral TAS signal
outputs of the EPU for monitoring.
Selects the vertical TAS signal
output of the EPU for monitoring.
Selects the fore-aft IAS signal
output of the EPU for monitoring.
Selects the lateral IAS signal
output of the EPU for monitoring.
Selects the static pressure output
of the EPU for monitoring.
Selects the differential pressure output
(total pressure less static pressure)
for EPU monitoring.
Selects the EPU +5 Vdc output of the
5V
EPU for monitoring.
INJV
Selects the EPU injection voltage output
of the EPU for monitoring.
+15V
Selects the EPU +15 Vdc output of the
EPU for monitoring.
2-2
|