TO 33D2-10-10-41
TM 55-6695-217-13
SECTION I
INTRODUCTION AND GENERAL INFORMATION
microphones
used
with
the
AN
A1C-10
1-1. INTRODUCTION. This technical manual contains
Intercommunication Set or similar systems. The tester
operating and maintenance instructions and an
also provides regulated power for the EEU-2P flash
illustrated parts breakdown for the Oxygen Mask,
protection goggles.
Headset, Microphone and Flash Goggles Tester, Type
MQ-1A, National Stock Number 6695-01-0970441. The
MQ-1A Tester is manufactured by Winding Specialists
contained in a portable case that requires only two
Co., Inc., Wichita, KS under part number 1854.
external connections: 1) connection to a supply of
breathing oxygen adjusted to 450 psi and 2) connection
1-2. PURPOSE.
The MQ-1A Tester (hereinafter
of the power cord to 115 volt, 60 Hz electrical power.
referred to as tester) is a preflight tester for the
All operating controls and instrumentation are located on
MS22001 oxygen mask and similar oxygen masks and
the control panel and are accessible with the cover
the P series helmet to discover evidence of leakage or
opened. Sufficient space Is provided between the
other malfunctions. It duplicates the oxygen, flash
closed cover and the control panel to permit storage of
goggles and communications system installed on
connecting cables, power cord and oxygen hose when
aircraft, except that this unit can be made available in
not in use. Additional physical characteristics and
personnel areas. The tester performs "talk out" checks
specifications are provided in subsequent paragraphs
of headsets and mask microphones, and of headset
and Table 1-1.
Table 1-1. Leading Particulars.
Input voltage
115 VAC, 60 HZ
Oxygen supply
450 PSI
Dimensions
14 in. long x 8 3/4 In. wide x 10 in. high
Weight
15 pounds
Figure 1-1. Oxygen Mask, Headset, Microphone and Flash Goggles Tester MQ-1A
1-1
|