TM 55-1520-4920-430-13
DIGITAL
STEP
RECEPTACLE
CONTROL/SWITCH
POSITION
NORMAL RESULTS
NO.
NOMENCLATURE
PIN NO.
1 . J6-L (line) to
1 . -5.605 to -6.195
(e)330
(e) ATT Synchro
Vac
J6-J
2. J6-K (line) to
2 . -5.605 to -6.195
J6-L
Vac
3. -11.21 to -12.39
3. J6-K (line) to
J6-J
Vac
Apply 10Vac to
9 to 11Vac on AC/
(7)
AC/DC VOLT-
300, 0, B,
DC VOLTMETER
CCDA J6-F (line)
1
METER CIRCUIT
to J6-C
SELECT switches
(8)
AC/DC VOLT-
30, 0, B,
9 to 11Vac on AC/
Apply 10Vac to
2
METER CIRCUIT
DC VOLTMETER
CCDA J6-D (line)
SELECT
to J6-E