TM 55-4920-430-13
VOLTAGE
DIGITAL
MEASUREMENT
CONTROL/SWITCH
STEP
POSITION
NO.
NOMENCLATURE
TEST PROCEDURES
NORMAL RESULTS
(a) None
(10) (a) RANGE s w i t c h
(a) 2 0 V
(a) None
S6
(b) APPLY
(o) RESPONSE
(b) None
(b) AC/DC VOLT-
TEST STIM
METER reads
switch S7
+5.5 to +8.5Vdc
after 7 sec.
(a) None
(a) GND
(11) (a) NORM ACCEL
(a) AC/DC VOLT-
METER continues
J2-52 switch
to display +5.5 to
S21
+8.5Vdc
(b) N O R M
(b) None
(b) NCRM ACCEL
(b) None
J2-52 switch
S21
(c) None
(c) RESPONSE
(c) None
(c) REMOVE
TEST STIM
switch S7
(12) (a) T I M E D E L A Y -
(a) None
(a) 00.000
(a) None
SEC switch S9
(b) APPLY
(b) None
(b) RESPONSE
(b) HOLD indicator
TEST STIM
comes on after
switch S7
1 to 3 sec.
(c) REMOVE (c) None
(c) RESPONSE
(c) HOLD indicator
TEST STIM
goes out.
switch S7
(a)
00,0,
B,
(a)
None
(a) None
( 1 3 ) (a) AC/DC VOLT-
METER CIRCUIT 0
SELECT
switches
(b) 20, 1
(b) CIRCUIT
(b) None
(b) None
SELECT
SELF TEST
switches
( c ) TIME DELAY-
00.075
(c) None
(c) None
(C)
SEC switch S9
(d) RESPONSE
(d) APPLY
(d) Record METER
(d) +5.86 to +6.00Vdc
TEST STIM
Reading
switch S7
4-62