Because of AFCS aircraft configuration, the relationship of the phase at
ATT synchro setting of 180 is in-phase with reference source.
l. Disconnect jumper wire from pin J3-V and connect to J3-U.
m. Check that the multimeter indicates 9.2 to 11.2 volts ac. Check that CHANNEL A and B wave-
forms are in phase.
n. If the phase requirement is not met, proceed as follows:
(1) Set the ATT synchro dial to 180.
(2) At the rear of the synchro, loosen three screws on the stator.
(3) Rotate the synchro stator 180.
(4) Repeat steps d. thru m.
(5) Disconnect multimeter and oscilloscope from test set.
(6) Set the 115V 400 Hz, and +28VDC TESTER POWER switches to OFF.
(7) Disconnect the power cable from the power source.
4-39. Installation of Panel (CRC).
a. Install the panel in the transit case.
b. Install the 18 screws around the edge of the panel. Tighten the screw until panel is secure in case.
4-40. FINAL TEST (CRC).
4-41. General.
These procedures ensure that the set meets performance standards for use, return to stock, or reissue.
These procedures are required when a test set is repaired or its performance is suspect.
4-42. Test Equipment Required. The following test equipment is required:
Specification
Function
Equipment
Vac 50 mV to 150V .5% (AC Sample)
Measure continuity, re-
Digital Multimeter (2 ea)
Vac 10 mV to 50V .1% (Rate Critical)
sistance ac and dc voltage
Measure Sine Wave
Dual Trace 0 to 100 mHz
350 Picosecond Rise Time
0.01 to 1.0 uf
Decade Capacitance Box
1.0 to 10.0 uf
(0.1% +0.5 pf)
Insert Resistance
10 ohms to 100 ohms
Decade Resistance Box
0.5 ohms to 1.1 megohms
1 hz to 1 mHz
Measure Frequency
Counter/Timer
Provides Test Voltage
0 to 36 vdc 0.5%
DC Power Supply (2 ea)
0 to 15 vac
Ref Volt Shift 90
Function Generator
Provides Test Voltage
0 to 115 vac .5%
AC Power Supply 400 Hz
Timer
0.1 sec min
Stop Watch