TM 55-4920-430-13
MILITARY
ITEM
SPECIFICATION
NOMENCLATURE
NUMBER
P-D-680
Dry Cleaning Solvent
1
CCC-C46A
Cloth, Cleaning
2
P-S-624
Soap, Toilet, Liquid and Paste
3
GGG-C-520
Cloth, Abrasive; Type II, Class I,
4
220 Grit or Finer
TT-N-95
Naphtha, Aliphatic, Type II
5
MIL-E-15090
Enamel Light Gray, Semi-Gloss, Type
6
III, Class 2
MIL-STD-595A
Enamel, Gloss Black, Color No. 17038
7
MIL-C-22750
Enamel, Flat Black
8
MIL-P-23377
Epoxy Primer
9
(a) Touch-up case or cover markings with gloss black enamel. (Item 7, table 3-1.)
b. Panel.
(1) Finish - Touch-up is not recommended.
( 2 ) Markings - For touch-up of lettering use flat black enamel. (Item 8, table 3-1.)
b. Remove the knob from the shaft.
c. Position the replacement knob on the shaft.
d. Tighten the two screws on the shaft.
a. Unscrew the lens from the lamp holder.
b. Lift out the defective lamp.
Insert the replacement lamp.
C.
d. Position the lens on the lamp holder and hand tighten.
3-7. Cable/Connector Repair.
Refer to TM 55-1500-323-25. Cable wiring diagrams are in fig. 3-1 thru 3-6 of this manual.
a. Remove the lens cover by inserting a thin screw driver or knife blade, under the edge of the cover
and apply pressure.
b. Install the lens cover, by placing the lens cover on the AC/DC VOLTMETER, and apply only
enough force to snap the lens cover on the AC/DC VOLTMETER.
|