Page Title: Table 4-9. Troubleshooting Turbine Gas Temp NO 1 or NO 2 (AVIM)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 55-4920-412-13&P f: Turbine Gas Temp NO 1 and NO 2. (1) Connect   Digital   multimeter   to   connector   NO  1 pin L (Hl) and M (LOW), using two leads. (2) Set    TURBINE    GAS    TEMP    NO    1    CAL/NOR switch  to  CAL,  HI/LO  switch  to  HI  and  variable  control fully CW. (3) Set  ON-OFF-SIM  ONLY  switch  to  SIM  ONLY. Digital    multimeter    will    indicate    between    +33.69    and +33.89 mvdc.  If not, perform Troubleshooting Table 4-9. (4) Set  TURBINE  GAS  TEMP  NO  1  HILO  switch  to LO.   Digital   multimeter   will   indicate   between   -0.1   and +0.1 mvdc.  If not, perform Troubleshooting Table 4-9. (5) TURBINE GAS TEMP NO 1 CAL/NOR switch to 1  NOR  and  adjust  variable  control  fully  CCW.    Digital multimeter will indicate between -0.5 and +0.5 mvdc.  If not, perform Troubleshooting Table 4-9. (6) Adjust     variable     control     fully     CW.          Digital multimeter      will   indicate   between   +41.30   and   +51.30 mvdc.  If not, perform Troubleshooting Table 4-9. (7) Set ON-OFF-SIM ONLY switch to OFF. (8) Disconnect  leads  from  connector  NO  1  pins  L (HI) and M (LOW) and connect to connector NO 2 pins L (HI) and M (LOW). (9) Repeat    (2)    through    (7)    above,    except    use TURBINE GAS TEMP NO 2 controls. Table 4-9.  Troubleshooting Turbine Gas Temp NO 1 or NO 2 (AVIM) NOTE Before performing troubleshooting, remove DC simulator A4 board and reconnect using extender board. Trouble Probable Cause Remedy No HI-CAL voltage NO 1 - (CR2),T3,(U2) First check loops 56(+) and 58(-) NO 2 - (CR3),T3,(U3) associated NO 1 for input 15 vac ±.5 vac and loops resistors and capacitors 27(+) and 30(-) NO 2 for 15 vac .5 NO 1 - TGT-U1 vac.  Check T3 if no voltage.  Replace NO 2 - TGT-U2 defective components, Figure 4-6, 4-7, FO-2, FO-5, or replace A4 board. HI-CAL VOLTAGE NO 1 - (R13) Use decade resistor box, and check or Indication out of tolerance NO 2 - (R20) replace malfunctioning components, Figures 4-6, 4-7, FO-2, FO-5 or replace A4 board. HI-CAL VOLTAGE NO 1 - (R54) or (R10)(U1) If trim resistors do not bring reading Indication out of tolerance NO 2 - (R53)(R17) or (U3) in tolerance replace malfunctioning after trim resistors checked or components, Figures 4-6, 4-7, FO-2, replaced (R13) or (R20) FO-5 or replace A4 board. LO-CAL VOLTAGE NO 1 - (S30) Replace malfunctioning components, Indication out of tolerance NO 2 - (S32) Figures 4-6, 4-7, FO-2, FO-5 or replace A4 board. Indication out of tolerance NO 1 - (R20) Replace malfunctioning components, In NOR-FULLY CCW NO 2 - (R21) Figures 4-6, 4-7, FO-2, FO-5 or replace A4 board. IN-NOR-FULLY NO 1 (R14)(R20) Replace malfunctioning components, CW NO 2 (R1114)(R21) Figures 4-6, 4-7, FO-2, FO-5 or replace A4 board. 4-14  Change 2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business