Table 3-2. Self-Test
Test procedure
Normal indication
1. INPUT POWER TEST
Before connecting cable, ensure +28 volt power supply
is turned off
Observe correct polarity. Reversed polarity can damage
the PSTS
1a. Connect (see figure 3-2)
(1) Terminal lugs of cable W311 to +28V power
supply
(2) W311P1 to PSTS J5
(3) Digital voltmeter (DVM) to primery power
1b. Turn on DVM
1c. Set switches as follows:
SWITCH
SETTING
MODE
OVERLOAD
FUNCTION
PS +17V
REFERENCE
0VDC
SELF TEST
OFF
INPUT POWER - UUT
OFF
INPUT POWER - PSTS
OFF
POWER SUPPLY
VEHICLE SENSE
OFF
INTERLOCK
OFF
IMU OVERTEMP
OFF
FLAG
OFF
COMP PS
OFF
1d. Turn on +28V power supply. If OVERTEMP indi-
cator lights, check polarity of cable W311
TIME HOURS meter is operating by observation
1e. Set INPUT POWER PSTS to ON
of comma oscillation. Fan is operating
1f. Press POWER SUPPLY TEST SET ON switch-
POWER SUPPLY TEST SET ON switch-indica-
indicator to on
tor lights
1g. Set MODE switch to NO LOAD
DVM indicates +26 to +30V
1h. Connect DVM positive test lead to SELF TEST
+28V test jack and negative test lead to SELF
TEST PWR RTN test jack
1i. Connect DVM positive test lead to SELF TEST
DVM indicates +9.9 to + 10.1V
+10V test jack and negative test lead to SELF
TEST PWR RTN test jack
|