ARMY TM 5-6675-309-14
MARINE CORPS TM 08840A-14/1
Function
Control, indicator, or connector
POWER SUPPLY
Test Jacks:
Used to measure PS regulated +28V
+28V
Used to measure PS regulated -28V
-28V
Used to measure PS regulated +17V
+17V
Used to measure PS inverter drive voltage
+INV DR
Used to measure PS unregulated +24V
+24V
UNREG
Used to measure PS auxiliary +24V
+24V AUX
Used to measure PS input voltage
PWR IN
Used to measure PS voltage for IMU ambient heater
AMB PWR HEAT
Used to measure PS voltage for IMU ambient cooler
AMB PWR COOL
Used to measure PS voltage summation for IMU environ-
AMB PWR SUM
mental control
Test jack for signal return
SIG RTN
Used to measure PS voltage for IMU transient heater 1
HTR 1
Used to measure PS voltage for IMU transient heater 2
HTR 2
Test jack for power return
PWR RTN
Used to measure PS 115 VAC 0 phase
115V
Used to measure PS 115 VAC 90 phase
115V
Used to measure PS 26 VAC 90 phase
26V
Used to measure PS control signal for IMU flag inhibit
IMU FLG INH*
Used to measure PS undervoltage
UNDER VOLT
Used to measure PS overvoltage
OVER VOLT*
Used to measure PS battery voltage
BATT
Used to measure computer blower voltage
COMP BLO
Used to measure IMU blower voltage
IMU BLO
COMP PWR SUPPLY
Test Jacks:
Used to measure COMP PS +5V
+5V
Used to measure COMP PS precision +15V
PREC +15V
Used to measure COMP PS precision -15V
PREC -15V
Used to measure COMP PS input voltage
PWR IN
Used to measure COMP PS voltage for CDU lamps
V LAMP
Used to measure COMP PS +15V memory
+15V MEM
Test jack for signal return
SIG RTN
Test jack for power return
PWR RTN
Used to measure COMP PS Power On Reset signal
POR*
Used to measure COMP OFF signal to COMP PS
COMP OFF*
|