ARMY TM 5-6675-309-14
MARINE CORPS TM 08840A-14/1
SERVICE UPON RECEIPT AND INSTALLATION
Section I. SITE AND SHELTER REQUIREMENTS
5 or a permanent installation that has +28V and
requirements for the PSTS.
variable 0 to +40V power can be used for PSTS
operation.
signed for operation in a sheltered maintenance shop.
The Semitrailer-Mounted Electronic Shop Set Number
Section Il. SERVICE UPON RECEIPT OF MATERIEL
report the damage on DD Form 6 (Packaging Improve-
ment Report).
b. Check the equipment against the component
listing in Appendix B and the packing slip to see if the
The PSTS is made up of delicate elec-
shipment is complete. Report all discrepancies in ac-
cordance with paragraph 1-2. The equipment should be
tronic equipment. Be extremely careful
when removing each item from container.
placed in service even though a minor assembly or part
that does not affect proper functioning is missing.
a. The items comprising the PSTS are packaged in
c. Check to see whether the equipment has been
two containers. One container holds the transit case
modified. (Equipment which has been modified will
with the PSTS. The other container holds the transit
have the MWO number on the front panel, near the
case with cable assemblies and maintenance manual.
nomenclature plate.) Check also to see whether all
currently applicable MWO'S have been applied. (Cur-
rent MWO'S applicable to the equipment are listed in
c. Press transit case pressure relief valve.
DA PAM 310-7.)
d. Remove equipment from transit cases.
d. For dimensions, weights, and volume of pack-
aged items, see SB 700-20.
a. Inspect the equipment for damage incurred dur-
ing shipment. If the equipment has been damaged,
|