TM5-6625-2694-13&P
Table 5-1.
Direct Support Troubleshooting (cont'd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step
3
Check Contactor Relay K4.
3 (+);
Measure voltage across terminals 1 (-) to
should be 24 VDC.
terminals 5 (+)
to 4 (-);
b.
Measure voltage across
should be 0 VDC.
Refer
and  replace Contactor
c.
if measurement across
terminal 1 to terminal 3
4  to
terminal
and  measurement
across
is  24  VDC
terminal 5 is NOT 0 VDC.
4.
PARTIAL LOAD APPLIED TO GENERATOR.
Step 1.
Check Contractors K1 and K2.
terminal
and
Measure
a.
voltage across terminal X1
X2 of each contactor.
Should read 24 VDC.
applied  to  terminals
X1  and  X2,
b.
With 24 VDC
input terminals of
Contactor to
measure voltage from
to LO.
terminals  of  Contactor
LO and from  output
Measurements should be equal.
and replace  Contactor if
c.
measurements  from input and  output terminals to LO are
NOT equal.
5-6