Table 3-9. Sensors DS Maintenance Troubleshooting - Continued
Figure 3-15. Radio Frequency Motion Sensor Functional Block Diagram (Transmitter) (1 of 2)

Integrated Commercial Intrusion Detection System (Icids) Page Navigation
  122    123    124    125    126  127  128    129    130    131    132  
img
. .
TM 5-6350-275-24&P
Table 3-9. Sensors DS Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. RADIO FREQUENCY MOTION SENSOR FAILURE (continued)
Step 7. Place multimeter negative lead on TB1 pin 1 and positive lead on pin 2. The multimeter should read
from +11 to +15 v.
If multimeter reading is correct, go to step 8.
If multimeter does not read between +11 and +15 v, replace input power source.
Step 8. Place multimeter negative lead on TB1 pin 9 and positive lead on Test Point TP5. The multimeter
should read between +3.5 and +5.5 v.
If multimeter reading is correct, replace RFMS Receiver PWA (Para. 3-124).
If multimeter reading is not correct, replace RFMS Transmitter PWA (Para. 3-124).
3-55