Table 5-1. Troubleshooting Procedures - Continued
Figure 5-1. Processor, Vibration Signal with Troubleshooting Test Points

Maintenance Manual For Control Unit, Alarm Set C-9412/Fss-9(V) -4 Page Navigation
  20    21    22    23    24  25  26    27    28    29    30  
img
TM 5-6350-264-14&P-4
NAVELEX EE 181-AA-OMI-050/E121 DT546-M9442
T.O. 31S9-2FSS9-1-4
Table 5-1. Troubleshooting Procedures - Continued
Trouble
Probable cause
Corrective action
4. (cont)
c. Loose interconnect-
Ensure that all conduit and wire con-
ing wiring.
nections are tight.
d. Gain or sensitivity
NOTE
controls set too
low.
BEFORE touching any gain or
sensitivity controls, note their
settings so that they may be
returned to their original posi-
tions after testing.
Check settings of Detector gain and
Processor sensitivity controls to
ensure that they are not set to
minimum (1).