TM 5-6350-264-14&P-4
NAVELEX EE 181-AA-OMI-050/E121 DT546-M9442
T.O. 31S9-2FSS9-1-4
Table 5-1. Troubleshooting Procedures - Continued
Trouble
Probable cause
Corrective action
4. (cont)
c. Loose interconnect-
Ensure that all conduit and wire con-
ing wiring.
nections are tight.
d. Gain or sensitivity
NOTE
controls set too
low.
BEFORE touching any gain or
sensitivity controls, note their
settings so that they may be
returned to their original posi-
tions after testing.
Check settings of Detector gain and
Processor sensitivity controls to
ensure that they are not set to
minimum (1).
5-19