Table 5-1. Troubleshooting Procedures - Continued
Trouble
Probable cause
Corrective action
2. (cont)
c. (cont)
that secure PC board to chassis. Lift
PC board out of chassis.
(2) To install new PC board, orient board
so the terminal strips are adjacent to
conduit entrance holes. Secure the
PC board to chassis with screws.
Connect wires to TB1 and TB2. Adjust
sensitivity control per instructions in
TM 5-6350-264-14/1.
a.
If PC board is good, check pick-up
d. Bad Detector pick-
assembly in Detector. Disconnect red
up assembly.
and black leads from PC board. Set
connect meter leads to red and black
leads.
Meter should indicate over
10,000,000 ohms.
b.
If this indication is not present, replace
pick-up assembly.
(1)
To
remove
pick-up
assembly,
disconnect red and black leads from
PC board. Remove screws that secure
assembly to mounting surface, and
remove assembly.
(2)
To install new pick-up assembly, orient
assembly so that red and black leads
are toward PC board. Tilt assembly so
that edge nearest PC board can be
slipped under PC board.
Insert
assembly into chassis, flat against
mounting surface, and secure it with
screws. Connect red and black leads
to PC board.
NOTE
BEFORE touching any gain or sensitivity
controls, note their settings so that they may
be returned to original positions after testing.
e. Gain or sensitivity controls
set too high.