CHAPTER 1. INTRODUCTION
Figure 1-4. Identification Plate, Transceiver

Maintenance Manual For Control Unit, Alarm Set C-9412/Fss-9(V) -2 Page Navigation
  1  2  3    4    5    6    7  
img
. .
TM 5-6350-264-14&P-2
NAVELEX EE181-AA-OMI-030/E121 RT1161 M9443
T.O. 31S9-2FSS9-1-2
Figure 1-2. Ultrasonic Motion Signal Transceiver
Width ........................................ 3.4 inches (8.6 cm)
1-9. TABULATED DATA.
Depth ........................................ 2.2 inches (5.6 cm)
a. Identification Data. Two plates, identification
and NSN, are mounted inside each chassis. Plates
Color (chassis) Gray per Federal Standard 595,
for the Processor are shown in figure 1-3 and for the
color chip 36440, MIL-C-22751
Transceiver in figure 1-4.
Environmental (operational)
b. Equipment Characteristics.
Temperature range -20 to +150 F (-29 to
Weight
+650C)
Processor ................................... 6.5 pounds (2.9 kg)
Relative humidity........................ Up to 95%
Transceiver ................................ 6.0 pounds (2.7 kg)
Environmental (nonoperational and storage)
Dimensions (overall)
Temperature range..................... -30 to +165F
(-34 to +740C)
Processor
Relative humidity........................ Up to 95%
Height ................................ 9.7 inches (24.6 cm)
Shock..................... 20 g for 11 ms duration plus bench
Width ................................. 10.2 inches (25.9 cm)
handling shock
Depth ...................................... 2.1 inches (5.3 cm)
Vibration ................................Withstands transportation
conditions
Transceiver
Sensitivity ..............................65 dB, referenced to
0.0002 microbar, between 25.3 and 27.3 kHz
Height ................................ 17.9 inches (45.5 cm)