TM 11-7010-201-40-5/ET821-AA-MMI-050/E154 MTS/T O 31S5-2TSQ73-2-5
NOTE
Ensure that wire and pin (29) or socket (27) is fully seated into connector plug (26 or 28).
(2) Slide metal shell and hood down cable (25) until it mates with connector plug (26 or 28).
(3) Secure metal shell and hood to connector plug (26 or 28) with four screws and two nut plates.
(4) Insert two locking screw shafts into connector, and install knurled knobs using pins removed in paragraph 5-
24a, step (1).
(5) Tighten two screws of cable clamp until wires are held securely.
5-25. Connector Plug Removal and Replacement. Either connector plug (26 or 28) may be removed and replaced by
following the connector plug electrical contact pin (29) and socket (27) removal and replacement procedures (paragraphs
5-24a and 5-24b) for all connector plug electrical contact pins (29) or sockets (27) of appropriate connector plug (26 or
28).