A10 consists of three phototransistor and amplifier
plied through diode CR24 to the DATA lamp thus lighting
assemblies A1 through A3 mounted m a column Two
the lamp
(5) Control relays K1 and K2. Control relays
razor blades, positioned in close proximity to each
phototransistor assembly, establish the aperture (0.0115
K1, K2 and diodes CR16 and CR17 in conjunction with
+ 0.001 inch) which admits light onto the phototransistor
lay K1 and diode CR1 (located on the chassis), function,
Bridge assembly photosensitive transistor output signals
to control application of the + 28-volt dc pulse power to
are processed by the FWD, CTR, and AFT variable
the shutter mechanism assembly for tripping the shutter
resistor controls R1, R2 and R3 and applied through
curtain mechanism When depressed, SHUTTER TRIP
FOCAL  PLANE  SHUTTER  switch  S8  to  shutter
switch S5 applies + 28 volts dc to pin D of SHUTTER
assembly test board and components assembly A8.
connector J5, through pins A2 and A3 relay K2 to pin X1
Here, the signals are amplified and then applied through
of relay K1 causing it to energize When relay K1 is
SHUTTER ASSY TEST switch S7 to SCOPE + B,
energized +28 volts dc is applied pins C and L of
SCOPE + A, COUNTER START and COUNTER STOP
SHUTTER MECHANISM connect J3.
d. Bridge Assembly A10 (fig 2-2) Bridge assembly
binding posts J12, J10, J8 and J9 respectively.
2-5