C1, TM 11-6625-646-15
Control
Function
Adapter Switch S6 (not readily acces-
Two-position 10-pole rotary switch. Position A adapts the test set cir-
sible) (14).
cults for H-46 or 107 SAS amplifiers. Position B adapts the test set
circuits for CH-47 SAS amplifiers. This switch is factory preset at B.
PUMP Switch S2 (21) ....................................... Three-ampere circuit breaker switch; connects and protects the 115-
volt 60-cycle ac circuit to the pump motor.
AXES METERS READ Switch S4 (4). .............. Double-pole toggle switch; controls relays on the actuator simulator
cards which connect the PITCH, ROLL, and YAW AXIS meters to
measure the SAS amplifier channel output to the extensible link
torque motor (solenoid) at OPEN LOOP and the simulated link feed-
back voltage at CLOSED LOOP.
AIRSPEED REG Valve (23) . ........................... Air valve. Controls the amount of air pressure to the SAS amplifier
airspeed sensor.
DIFF PRESS. REG Valve (18) ........................ Air valve. Controls the amount and direction of air pressure to the
SAS amplifier sideslip sensor.
ROLL GYRO SIMULATOR
Single-pole, 5-position rotary switch. Applied simulated roll signals to
Switch S101 on adapter
SAS amplifier 114E3030-49. The function of each switch position is
(114E5987-8 only).
as follows:
OFF-input to roll signal demodulator is short circuited.
R ROLL-applies 3right roll signal to SAS amplifier.
R LIM-applies maximum right roll signal to SAS amplifier.
L ROLL-applies 3left roll to SAS amplifier.
L LIM-applies maximum left roll signal to SAS amplifier.
GAIN SWITCH S101 on adapter
Spst toggle switch. Controls pitch axis gain, simulating ground/air
(114E5987-8 only).
operation when switch is set to GRD or AIR position respectively.
Table 4-2. Indicators
Indicator
Function
FUNCTION Meter M1 (2).................................. Zero-center voltmeter, calibrated -20 to +20, with a red sector be-
tween -8 and -12 and a green sector between +8 and +12;
indicates voltages at the circuit point selected by the FUNCTION
switch.
YAW AXIS Meter M2 (6) .................................. Zero-center voltmeter, calibrated -10 to +10 and -1 to +1; in-
dicates output of yaw channel or simulated extensible link feedback
(cancellation) voltage.
ROLL AXIS Meter M3 (9).................................. Zero-center voltmeter, calibrated -10 to +10 and -1 to +1; indicates
output of roll channel or simulated extensible link feedback (can-
cellation) voltage.
PITCH AXIS Meter M4 (10) .............................. Zero-center voltmeter, calibrated -10 to +10 and -1 to +1; indicates
output of pitch channel or simulated extensible link feedback (can-
cellation) voltage.
FULL GAIN Indicator Lamp DS2 (7) ................. Indicator lamp; goes out when the SAS amplifier gain control relay
operates.
POWER Indicator DS1 (11) .............................. Indicator lamp; lights when 400-cycle power is applied to the test set.
PUMP INDICATOR DS3 (20) ........................... Indicator lamp; lights when 60-cycle power is applied to the pump
motor.
AIRSPEED INDICATOR (24)............................ Air pressure indicator; calibrated 0 to 150 knots. Indicates the ram
air pressure applied to the pitot connection of the SAS amplifier.
DIFF. PRESSURE Indicator (15) ..................... Zero-center air pressure indicator; calibrated L15 to R15; indicates
the relative amount and direction of differential pressure connected
to the L and R sideslip connections of the SAS amplifier.