TM
11-6625-467-34
b. Using the module extender board, extend RF
() on the circuit card and adjust R18 for +27.5 volts
amplifier/detector/switch circuit card HV3 above
dc on the ME-202/U.
the card cage.
g. Remove the extender card and replace the
+28-volt deregulator circuit in the card cage.
c. Connect power to the equipment and set the
POWER switch to ON.
3-19. --28-Volt Regulator Adjustment
d. Pull the shaft of interlock switch S12 to the
override position.
Perform the following procedures to adjust the
e. S e t t h e P O W E R S E L E C T O R s w i t c h t o
28-volt regulator:
NORMAL.
a. Remove the test set from the case.
f. Set the CIRCUIT SELECTOR switches to
b. Using the module extender board, extend
0500.
28-volt regulator card HU3 above the card cage.
g. C o n n e c t t h e A N / G R M - 5 0 ( v h f s i g n a l
c. Connect power to the equipment and set the
generator) RF output to the RF VM 1 jack on the
POWER switch to ON.
d. Pull the shaft of interlock switch S12 to the
test set and set up the generator to produce a 3-
MHz, 63-millivolt, unmodulated output.
override position.
h. Push the PRESS TO TEST button on the test
e. S e t t h e P O W E R S E L E C T O R s w i t c h t o
set and adjust R1 on the circuit card for a reading of
NORMAL.
90 percent on the TEST METER.
f Connect the ME-202/U between J2 () and J3
(+) and adjust R6 on the circuit card for 27.5 volts
65-MHz. (Insure that the output is still 63
dc on the ME-202/U.
millivolts. )
g. Remove the module extender board and re-
j. Press the PRESS TO TEST button and adjust
place the 28-volt regulator card in the card cage.
capacitor C5 on the circuit card for a reading of 90
3-20. Audio Amplifier/Detector Gain
percent on the TEST METER.
Adjustment
k. Repeat procedures given in g through j a b o v e
until no further adjustment is necessary.
P e r f o r m the following procedures to adjust the
l. Remove the extender card and replace the RF
audio amplifier/detector gain:
a. Remove the test set from the case.
amplifier/detector/switch circuit card in the card
b. Using the module extender board, extend the
cage.
audio amplifier/detector circuit card HU7 above the
3-22. 150-Hz Oscillator/Counter Adjustment
card cage.
Perform the following procedures to adjust the 150-
c. Connect power to the equipment and set the
Hz oscillator/counter:
POWER switch to ON.
a. Remove the test set from the case.
d. Pull the shaft of interlock switch S12 to the
b. Using the module extender board, extend 150-
override position.
Hz oscillator/counter circuit card HU8 above the
e. S e t t h e P O W E R S E L E C T O R s w i t c h t o
card cage.
NORMAL.
c. Connect power to the equipment and set the
f. Set the CIRCUIT SELECTOR switches to
POWER switch to ON.
2200.
d. Pull the shaft on interlock switch S12 to the
override position.
tween J2 and ground on the audio amplifier/detec-
e. S e t t h e P O W E R S E L E C T O R s w i t c h t o
tor circuit card and adjust the 1 KC AMPL control
NORMAL.
on the front panel of the test set for 15 millivolts on
f. Set CIRCUIT SELECTOR switches to 3241.
the ME-30A/U.
h. Push the PRESS TO TEST button on the test
to J4 on the circuit card.
set and adjust R11 on the circuit card for a reading
of 70 percent on the TEST METER.
Table 3-5. Capacitor Frequency Adjustment
i. R e m o v e t h e m o d u l e e x t e n d e r b o a r d a n d
replace the audio amplifier/detector circuit card in
the card cage.
3-21. RF Amplifier/Detector Gain and
Frequency Response Adjustment
Perform the following procedures to adjust the RF
amplifier/ detector:
a. Remove the test set from the case.
3-44
|