TM 11-6625-409-12
Section II. DESCRIPTION AND DATA
1-7. Purpose and Use
a. Purpose.
Test Set, Radio AN/ARM-45(*),
AC
................... 115 volts, 400 cps, single
phase, at 2 amperes (when
provides the portable test facilities required for checking
AN/ARC-73 or AN/ARC-73A
the components of Radio Sets AN/ARC-73 and AN/ARC-
under test is equipped with ac
73A (Transmitter 17L-7A, Receiver 51X-2B, Dual
power supplies).
shockmount 390E-2, and Radio Set Control 614U-5 or
Frequency range..... 116 to 151 megacycles (in.
614U-6) and the aircraft wiring associated with these
0.05-megacycle increments).
components.
b. Use. The test set may be used either at a
Indicators:
Lamps (16)
Incandescent, 28 volts.
maintenance bench (independently of the associated
Meter:
aircraft wiring) to perform operational tests of the
Type ........... Dc milliameter, 0 to 1.9 ma
transmitter, receiver, and remote control unit (a above),
scale.
or it may be used within the aircraft to test the wiring and
Accuracy .... 2 percent of full-scale
control circuits associated with these components.
deflection.
1-8.
Tabulated Data.
Weight
................... 35 pounds.
Power requirements:
Volume ................... 2.1 cubic feet.
DC ..............27.5 volts at 1.5 amperes.
Dimensions:
Length ................ 18 inches.
Width .................. 11 inches.
1-9.
Items Comprising an Operable Radio Test
Height................. 10 3/4 inches.
Set AN/ ARM-45(*)
National stock No.
QTY
Nomenclature, Part No. And Mfr Code
NOTE
The part number is followed by the applicable 5-digit Federal Supply Code
for Manufacturers (FSCM) identified in SB 708-42.
Test Set Subassembly MX-3736/ARM-45, consisting of:
5821-00-673.3101
1
Control Radio Set, manual control type, 614U-6 a
1
Control Radio Set, manual control type, 614U-5
5995-00-903-4839
1
Electrical Power Cable Assembly (cable No. 1), 5180092583, 13499
6625-00-823-2583
1
Electrical Power Cable Assembly (cable No. 1A), 5180092583, 13499
6fi625-0823-2585
1
Electrical Power Cable Assembly (cable No. 2), 5180076113, 13499
6625-00-823-2587
1
Electrical Power Cable Assembly (cable No. 3), 7765480001, 13499
6625-00-823-2580
1
Radio Frequency Cable Assembly (cable No. 4), 5180076162, 13499
6625-00-823-2573
1
Radio Frequency Cable Assembly (cable No. 5), 5180076432, 13499
6625-00-823-2491
1
Cable Assembly Set. Electrical OA-2494/ARM-45 consisting of:
6625-00-823-2581
1
Electrical Power Cable Assembly (RF patch cable No. 1) 5180076042, 13499
66fi25-00-8232579
1
Radiofrequency Cable Assembly (RF patch cable No. 2) 5180076052, 13499
6625-00-087-0739
1
Electrical Power Cable Assembly (RF patch cable No. 3) 5180076312, 13499
6625-00-087-0737
1
Electrical Power Cable Assembly (Modulator Patch cable) 5180076322, 13499
6625-00-823-2591
1
Electrical Power Cable Assembly (Power patch cable No. 1), 5180076032, 13499
6625-00-087-0736
1
Electrical Power Cable Assembly (Power patch cable No. 2), 5180076082, 13499
6625-00-823-2582
1
Electrical Cable Assembly (Audio patch cable), 5180076072, 13499
6625-00-823-2586
1
Electrical Cable Assembly (RF/VIF patch cable), 5180076063, 13499
1
Case
1
Cover
Assembly Set, Electrical OA-2494/ARM-45 (para 1-13),
1-10.
Description of Test Set, Radio AN/ ARM-
and test cable assemblies (para 1-14). Storage facilities
45(*)
for the test cable assemblies and the components of OA-
2494/ARM-45 are provided within the metal case of the
The AN/ARM-45(*) consists of Test Set Subassembly
MX-3736/ARM-45. Power for the
MX-3736/ARM-45 (para 1-11), Radio Set Control 614U-6
(para 1.12) or Radio Set Control 614U-5, Cable
1-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |