TM 11-6625-3056-12
3-5.
SYNC-TIME MEASUREMENTS (cont)
Set DATA ON/OFF to ON:
Display will rapidly (almost instantly) advance count (1000 counts per second).
When TD-1065 has acquired sync, it will output data to the TS-3981. The TS-3981 ACTIVITY
indicator will light, and display count will stop advancing.
The display, at the time it stops advancing, is the number of milliseconds it took the TD-1065
to acquire sync, typically 5 to 20 milliseconds. Readings of 0 to 4 milliseconds are due to
noise and are erroneous.
3-7
|