3-5.
SYNC-TIME MEASUREMENTS
General
To measure the length of time it takes the TD-1065 to acquire sync after an input signal is applied,
proceed as follows:
NOTE:
This test is normally not performed in the field. Erroneous results are possible with noisy signals.
Setup
At TD-1065, disconnect cable from MUX channel to be tested (1-4, 5-8, or 9-12). Under some
conditions with these cables connected, noise is introduced in the channel and is misinterpreted
by the TS-3981 as a signal. The result is a sync time reading much shorter (O to 4 ms) than the
actual sync time (5 to 20 ms).
Procedure
Set TS-3981 controls as follows:
POWER
ON
PATTERN
LONG
OPERATION
4W
CORRELATOR LOOP
OPEN
DATA ON/OFF
ON
RATE SELECT
7 (32 kb/s)
DISPLAY SELECT
ERRORS
ACTIVITY indicator will be lit.
Press RESET:
Display will read 0.
If display does not stay at 0 and increases count rapidly, turn DATA ON/OFF back and forth
between ON and OFF several times. If display still increases count rapidly, polarity of DATA
OUT and/or DATA IN connectors may be reversed. Reconnect with opposite polarity and
repeat procedure.
Press SINGLE ERROR several times.
Display will advance 1 count each time SINGLE ERROR is pressed. This ensures setup is
operating properly.
Set DATA ON/OFF to OFF and DISPLAY SELECT to SYNC TIME MSEC.
Press RESET:
Display will read O.
3-6