TM 11-6625-3056-12
2- 1.
FRONT PANEL CONTROLS, INDICATORS, AND CONNECTORS (cont)
Function
Name
Type
10
DATA IN
Dual binding
Accept field wire or banana plugs.
posts/banana
Internal connections depend on setting
jacks
of OPERATION control:
OPERATION
Control
DATA IN Connections
4W
Connected to input circuits
to provide balanced data input.
2W-T
Open
2W-R
Open
11 DATA ON/OFF
Two-position
Controls signal to data output circuits:
toggle switch
ON
Signal is connected to data
output circuits. If OPERATION
control is set to 4W or 2W-T,
data is available at DATA OUT
connectors.
OFF
Signal is not connected to data
output circuits and is not avail-
able at DATA OUT connectors.
ERRORS
BNC connector
Provides output pulse for each error
detected.
13
DISPLAY
Three-position
Selects operation of display
SELECT
rotary switch
OFF
Display is blank.
ERRORS
Display is number of errors
detected.
SYNC TIME
MSEC
Display is length of time, in
milliseconds, from time DATA
ON/OFF control is set to ON to
time a data.
14
FREQ MON
BNC connector
Provides output pulse at same rate as
data output (as set by RATE SELECT control).
Independent of DATA ON/OFF
and OPERATION controls.