2-1.
FRONT PANEL CONTROLS, INDICATORS, AND CONNECTORS (cont)
Name
Type
Function
3
CORRELATOR Two-position
Sets receiver to synchronization mode
LOOP
toggle switch
or error-detection mode:
OPEN
Received data is loaded continuously into receiver PR
CLOSED
Receiver PR Generator operates independently.
4
DISPLAY
Four-digit
Displays measurement data (errors or sync
time) as determined by (12) DISPLAY SELECT control.
LED display
5
RESET
Momentary
Resets display to 0 each time it is
pushbutton switch
pressed.
6
SINGLE
Momentary
Injects a single error into the output
ERROR
pushbutton switch
data pattern each time it is pressed.
7
ACTIVITY
Green indicator
Indicates presence of data signal to
DATA IN circuits, when lit.
8
RATE SELECT Eight-position
Selects rate of DATA OUT and DATA IN
thumbwheel switch
circuits:
O
38.4
kb/s
1
.6
kb/s
2
1.2
kb/s
3
2.4
kb/s
4
4.8
kb/s
5
9.6
kb/s
6
16
kb/s
7
32
kb/s
9
DATA OUT
Dual binding
Accept field wire or banana plugs.
posts/banana
Internal connections depend on setting
jacks
of OPERATION control:
OPERATION
Control
DATA OUT Connections
4W
Connected to output circuits
2W-T
to provide balanced data output.
2W-R
Connected to input circuits
to provide balanced data input.