TM 116625-3024-14/EE641-AC-MMA-010/E14 SYSEX/TO 33AA50-5-1-1
Table 3-1. Front Panel Controls and Indicators (Continued)
Control/Indicator
Function
RUN FORWARD
Commands FORWARD tape motion in the
transport. The read circuits and the error counter
are enabled with forward tape motion. FAST tape
motion may be combined with RUN FORWARD.
STOP
Terminates all operations under control of the
Exerciser. The REWIND operation cannot be
stopped, once in progress.
All Motion Control and Data Control switches are
locked out when the STOP indicator is not lighted,
(STOP function disabled).
SIG GND
Used as return for all Motion Control and Status
Indication test jack signals.
EXT. START CONNECTOR
(Used with BLOCK MODE only.)
Starts the next block operation when the voltage at
the EXT. START input connector is above 2.5 Vdc
or the input is open.
(Used with BLOCK MODE only.)
SYNC. CONNECTOR
Provides a TL output pulse (open collector) at the
start of each block, when BLOCK MODE has been
selected.
POWER ON/OFF
SYSTEM ON/OFF
Exerciser power switch. Provides power to all
Exerciser circuits. An automatic power reset sets
the STOP and WRITE RESET indicators to ON. All
other Data Control and Motion Control indicators
are off.
3-6
|