TM 11-6625-2976-40
2-14. VOR BEARING SELECTOR CONTROL ALINEMENT. (CONT)
1. Adjust oscilloscope TiME BASE variable control and rotate VOR bearing selector control until
oscilloscope display matches detail A (1).
2. Loosen two setscrews (2) on VOR bearing selector control (3).
3. Lineup control index mark(4) with front panel 000 display.
NOTE
Do not loosen setscrew on variable (inside) control (5).
4. Retighten two setscrews (2) and verify that oscilloscope waveform still matches detail A (1).
2-56
|