TM 11-6625-2975-40
2-17. TROUBLESHOOTING
CHARTS. (CONT)
CHART 2-1
Performance Test Failure Troubleshooting
(Sheet 11 of 11)
TABLE A
TEST POINT LOGIC VOLTAGES
TEST SET
RF LEVEL (-dBmW)
DISPLAY SETTING
RF1
RF64
RF32
RF16
RF8
RF4
RF2
-7
HI
HI
HI
HI
LO
HI
HI
HI
HI
HI
LO
-8
HI
HI
HI
-10
HI
LO
HI
HI
HI
HI
HI
LO
HI
HI
-14
HI
HI
HI
HI
HI
-20
LO
LO
HI
HI
LO
HI
HI
HI
-48
HI
LO
LO
HI
LO
-91
LO
LO
HI
HI
LO
HI
LO
NOTE
If using voltmeter, HI voltage is between 10.0 and 14.0 vdc and LO voltage is 0.4 vdc or
less.
2-30
|