TM 11-6625-2975-12
3-6. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES.
ORGANIZATIONAL PMCS, MONTHLY SCHEDULE
ITEM
TO BE
ITEM
PROCEDURES
INSPECTED
NO.
I
Inspect for cleanliness. If necessary, clean (para 3-7).
Blower Filter
1
I
Perform operational check (para 3-9).
Test Set
2
3-7. BLOWER FILTER CLEANING.
MATERIALS/PARTS: Detergent, G.P. liquid (item 5, appendix E)
EL9LX053
Slide filter (1) out of filter cage (2) on rear of test set.
1.
2. Using mild detergent in water, thoroughly wash filter and rinse in clear water.
WARNING
In following step, do not use extremely hot air to dry filter. Damage to filter could result.
Compressed air shall not be used for cleaning purposes except where reduced to less
than 29 psi and then only with effective chip guarding and personnel protective equip
ment. Do not use compressed air to dry parts when TRICHLOROTRIFLUOROETHANE has
been used. Compressed air is dangerous and can cause serious bodily harm if protec-
tive means or methods are not observed to prevent chip or particle (of whatever size)
from being blown into the eyes or unbroken skin of the operator or other personnel.
3. Airdry filter.
4. Slide filter (1) in filter cage (2).
3-4
|