TM 11-6625-2975-12
2-4. OPERATING PROCEDURES. (CONT)
VOR RADIAL SELECTION AND ADJUSTMENT
EL9LX030
Select any standard VOR rf carrier frequency from table 2-11, and enter it into test set
1.
(FREQUENCY/MODE SELECTION, steps 1 through 6, page 2-16).
2. Press and hold RDL/DDM key until it lights.
NOTE
RDL/DDM key lights indicating DATA ENTRY keys are ready to be used for entry of
selected radials. When RDL/DDM key is pressed, RF FREQ key lamp goes off. VOR
radial is selectable from 000.00 to 359.99 degrees in 0.01-degree increments.
EL9LX031
Using DATA ENTRY keys, enter selected VOR radial.
3.
4. Press and release ENTER key.
2-23