TM 11-6625-2975-12
1-8. SAFETY, CARE, AND HANDLING.
Observe all warnings, cautions and notes in this manual. This equipment can be extremely dangerous
if these instructions are not followed. Make sure the following caution Is observed as well.
CAUTION
When operating the test set, do not restrict airflow through the blower filter.
After cleaning the blower filter, make sure it is completely dry before installing it In the
blower filter cage.
Section II EQUIPMENT DESCRIPTION
Para
Page
Subject
Equipment Characteristics, Capabilities, and Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Location and Description of Major Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10
Equipment Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1.9.
EQUIPMENT CHARACTERISTICS, CAPABILITIES, AND FEATURES.
PURPOSE OF TEST SET
A solid-state signal generator designed for bench testing VOR, Iocalizer, glideslope, and marker
beacon receivers.
FEATURES
COMP BNC, AUX BNC and DEMOD BNC connectors
50/60 Hz operation
Input power identification plate
115 or 230 vac operation
The test set is wired for 115 vac operation; however, the power transformer input wiring
can be changed to permit 230 vac operation. This change is made at the next level of
maintenance.
OPERATIONAL CAPABILITIES
Test set operational capabilities include:
VOR, Iocalizer, glide slope, and marker beacon signals
Selectable VOR radials from 000.00 to 359.99 degrees
Deletion of modulation tone or tones for flag checks
1020 Hz audio tone for identification signal
Standard Iocalizer and glide slope rf frequency pairings
Variable rf frequency to check receiver selectivity
Variable rf output level to check receiver sensitivity
Variable DDM in 0.001 increments.