natural oils, prolonged contact with skin
NOTE
should be avoided. When necessary,
Replace POWER ON indicator lamp by
use gloves which the solvent cannot
turning it clockwise.
penetrate.
If the solvent is taken
(1) Insert lamp in lens assembly.
internally,
consult
a
physician
(2) Screw lens assembly into the socket by
immediately.
turning it clockwise.
b. Remove grease, fungus, and ground-in dirt
(3) Check lamp for proper operation by
from the equipment using a soft cloth dampened (not
performing BITE test (para 2-5b(2)).
wet) with trichlorotrifluoroethane.
c. Digital Tester Indicator Lamp Replacement.
c. Remove dirt from connectors with a brush;
To replace an indicator lamp in the digital tester refer to
remove moisture with a dry cloth.
TM 11-6625-2951-13.
d. Clean control-interface unit TEST NUMBER
3-15. Fuse Replacement (Digital Tester)
display window with a soft clean cloth moistened with
To replace the 10 ampere FAST fuse in the rear of the
water. If dirt is difficult to remove, a mild soap may be
digital tester proceed as follows:
used.
WARNING
e. Clean counter display window on digital
Before replacing fuse, disconnect power
tester with a soft cloth moistened with water. If dirt is
cable from power source.
difficult to remove, a mild soap may be used.
a. Press fuse holder cover in, turn
f.
Clean switches and control knobs using a
counterclockwise and remove cover.
soft cloth dampened with water. Use mild soap if
NOTE
necessary.
The fuse comes out of the holder with the cover.
3-14. Removal and Replacement of Indicator
b. Pull fuse out of cover.
Lamps
c. Place new fuse in fuse holder cover.
a. Control-Interface Unit Indicator Lamp
d. Insert fuse in holder, press and turn fuse
Removal To remove an indicator lamp from the control-
holder cover clockwise to locked position.
interface unit, proceed as follows:
3-16. Testing After Repair
(1) Unscrew and remove the lens
After a repair has been completed on the control-
assembly by turning it counterclockwise.
interface unit or digital tester proceed as follows:
NOTE
a. Set the control-interface unit and digital
The lamp comes out of the socket with
tester controls in accordance with table 2-4.
the lens assembly.
b. Perform the BITE test in accordance with
(2) Pull lamp out of lens assembly.
paragraph 2-5b(2).
NOTE
c. Perform the digital tester self test in
POWER ON indicator lamp is removed
accordance with TM 11-6625-2951-13.
by
pressing
in
and
turning
counterclockwise.
b. Control-Interface Unit Indicator Lamp
Replacement. To replace an indicator lamp in the
control-interface unit proceed as follows:
3-3
|