Table 2-1. Control-Interface Unit Controls. Indicators, and Connectors
Control, indicator, or connector
Function
POWER ON/OFF switch
In ON position, ac power is applied and control-interface unit is turned on. In OFF position,
control-interface unit is turned off.
POWER ON indicator
Lights (red) when POWER ON/OFF switch is placed in ON position to indicate presence of ac
power.
ELAPSED TIM meter
Indicates number of hours that control-interface unit has been in operation.
MODE SELECT switch
Six-position rotary switch that switches necessary input power to encoder or during
unit tests and input power to microprocessor or standard logic cards during card tests. Switch
positions are as follows:
POWER OFF: No input power is applied to UNIT TEST POWER or MODULE TEST con-
nectors.
ENC UNIT TEST: Power is applied to the UNIT TEST POWER connector for encoder unit
testing
DEC UNIT TEST: Power is applied to UNIT TEST POWER connector for decoder unit
testing.
ENC MODULE TEST: Power is applied to MODULE TEST connector for encoder micro-
processor or standard logic card test (as applicable).
DEC MODULE TEST: Power is applied to the MODULE TEST connector for decoder
microprocessor or standard logic card test (as applicable).
STE MODULE TEST: Power is applied to the MODULE TEST connector for control-inter-
face unit microprocessor or standard logic card test (as applicable).
MODE IN ERROR indicator
Pulses (yellow) if MODE SELECT switch is placed in wrong position for a particular test (e.g.,
decoder microprocessor or standard logic card prepared for test with MODE SELECT switch
in DEC UNIT TEST position).
MODE/POWER UNIT TEST ON indicator
Lights (green) when MODE SELECT switch is in ENC UNIT TEST or DEC UNIT TEST
position.
MODE/POWER MODULE TEST ON indicator
Lights (green) when MODE SELECT switch is in ENC MODULE TEST, DEC MODULE
TEST or STE MODULE TEST.
MODE/POWER SHORT indicator
Lights (red) during an ENC MODULE TEST, STE MODULE TEST or DEC MODULE
TEST when a power problem is detected.
TEST NUMBER ON indicator
Lights (white) when a program card test is being run and goes out at completion of test.
TESTNUMBER display
Provides three-digit display of particular program card test being run. Also, provides fault loca-
tion information when control-interface unit BITE test is being run.
UNIT TEST POWER connector
Provides interface, between encoder or decoder and control-interface unit.
MODULE TEST connector
Provides interface between control-interface unit and microprocessor or standard logic cards.
AN/UYM-7 connector
Provides interface between control-interface unit and digital tester.
MODULE TEST circuit card rack
Provides connectors for encoder, decoder and control-interface unit, microprocessor and.
standard logic cards, to control-interface unit.
Power input connector J12
Provides for connecting line power to control-interface unit.
Circuit breaker CB1
Pushbutton (push-to-reset) 3-phaae circuit breaker in 115-volt ac, 4O0-Hz, 3-phase input line.
Interrupts current in excess of five amperes.
b.  Digital Tester (fig. 2-4). The digital tester
connectors The controls, indicators, and connectors
are shown in figure 2-4 and described in table 2-2.
has both front and rear panel controls, indicators, and
Table 2-2. Digital Tester Controls. indicators, and Connectors
Control, indicator, or connector
Function
POWER switch-indicator
In up position, digital tester is turned on and red indicator is on. In down position, digital tester
is turned off and red indicator is off.
UUT POWER switch-indicator
In up position, dc power is applied through interface connector to the control-interface unit for
microprocessor or standard logic cards under test and indicator lights red In down position,
no dc power is applied to cards and indicator is out.
TEST switch-indicator (two switches)
Pressing either of these momentary switches to down position initiates complete test sequence.
Red indicator is on while test is in progress. Pressing either TEST switch to up -100 initi-
ates tester front panel lamp test.
RECYCLE TEST switch- indicator
Pressing this momentary switch to down position initiates complete test sequence that is repeated con-
tinuously with a delay of approximately 3 seconds between test sequence. Red indicator is
on during recycle mode. Pressing TEST, RECYCLE TEST or CONT TEST switch-indicator
to down position stops recycle mode.
CONT TEST switch-indicator
Pressing this momentary switch to down position places digital tester in continuous test mode.
In this mode, red indicator is on and digital tester continuously generates test signals regard-
less of number of tests selected Pressing TEST, CONT TEST, or RECYCLE TEST switch-
indicator to down position stops continuous test mode.
PROBE connector
Provides interface between logic probe and digital tester.
2-6