TM 11-6625-2885-30/NAVAIR 16-35TS3614-2
RF OUTPUT LEVEL CHECK
3-13.
Test Equipment. Use the following test equipment or equivalent to check
a.
the RF- output level:
BTS (1)
TS-3615/ALQ-136(V)
PP-1104/G
Power Supply (2)
HP 435A
Power Meter (3)
Power Sensor (4)
HP 8481A
Adapter (5)
N female to SMA male
b.
Test Connections and Conditions. Using RF Adapter, connect RF sensor to
J2 of Transmitter Assembly 1A1, with FLTS connected as in paragraph 3-8.
Initial Test Equipment Setting.
Set the power meter range switch (6) to
c.
+10 dBm scale.
|