TM 11-6625-2885-30/NAVAIR 16-35TS3614-2
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (Continued)
FUNCTION
DEVICE
KEY
Controls
Allows application of +28 Vdc to the
1
ON/PWR Circuit Breaker
FLTS in the ON position and provides
overcurrent protection.
Allows selection of the STBY mode or
the OPR mode. In STBY mode no test
2
STBY/OPR Switch
signal is generated for either self-
test or equipment test.
Allows selection of LAMP TEST or
3
LAMP TEST/SELF-TEST Switch
SELF-TEST and is in the center posi-
( Momentary)
tion for normal or standby operation.
In LAMP TEST position, the GO/NO GO
and JAM lamps illuminate. In SELF-
TEST position, signals are generated
to check proper signal processing
between Receiver (1A3), Transmitter
(1A1), and Video (1A2) Assemblies.
Indicators
Lights white to indicate that the
4
JAM Indicator Lamp
RF power threshold has been exceeded
in either self-test or equipment
test.
Lights green to indicate proper
5
GO/NO GO Indicator Lamp
signal processing between Receiver
(1A3) , Transmitter (1A1), and Video
(1A2) Assemblies during self-test.
In equipment test, lights green to
indicate that proper signal process-
ing has occurred in LRU-1.
6
PWR Indicator Lamp
Lights green to indicate that +28 Vdc
is supplied to the power supplies in
Video Assembly 1A2.
Connectors
7
RCV J3
Connects video assembly to Receiver
Assembly 1A3.
8
XMT J2
Connects video assembly to Transmitter
Assembly 1A1.
9
PWR J1
Connects video assembly to CM set
LRU-1.
|