REPLACEMENT OF POWER SUPPLIES (Continued)
RF Modulation Assembly 1A3/1A4PS2 (+15 Vdc). Remove RF modulation
f.
assembly from BTS in accordance with paragraph 3-32a.
REMOVAL
(1) Place the RF modu ation assembly in an upside down position on the
test bench.
(2) Remove caution plate (1) - five pan head screws, lockwashers and
flat washers.
(3) Tag and unsolder the 115 Vac input wires (2) and the two output
wires (3) from Power Supply PS2.
(4) Remove the hex nuts, lockwashers and flat washers (4) from the
bottom side of the RF modulation assembly to which the power supply
is attached.
(5) Lower and remove PS2 (5) from the RF modulation assembly.