TM 11-6625-2884-30/NAVAIR 16-35TS3615-2
REPLACEMENT OF POWER SUPPLIES (Continued)
b.
Control Panel Assembly Power Supply 1A1PS2 (+15 Vdc). Remove Control
Panel Assembly 1A1 from the BTS in accordance with paragraph 3-32c and
perform the following:
REMOVAL
(1) Place the control panel in an upside down position on the test
bench.
(2) Remove caution Plate (1) - four pan head screws, lockwashers and
flat washers.
(3) Tag and unsolder the 115 Vac input wires (2) and the two output
wires (3) from Power Supply PS2.
(4) Remove four pan head screws and lockwashers (4) securing PS2 to
power supply bracket.
(5) Lower and remove PS2 (5) from the control panel.
REPLACEMENT
(1) Position replacement +15 Vdc Power Supply PS2 (5) on control
panel.
(2) Fasten PS2 to power supply bracket, using four pan head screws
and lockwashers (4).
(3) Solder 115 Vac input wires (2) and two output wires (3) to Power
Supply PS2, observing dc polarity.
(4) Install caution plate (1) with four pan head screws, lockwashers
and flat washers.
(5) Replace control panel in BTS according to paragraph 3-32d.
3-88
|