TM 11-6625-2884-12/NAVAIR 16-35TS3615-1
TABLE 2-2.
CONTROL PANEL ASSEMBLY CONTROLS, INDICATORS,
AND CONNECTORS (Continued)
REFERENCE
DEVICE
FUNCTION
CONTROL INDICATOR
Controls status of LRU-1.
OPR/STBY/OFF pull-
to-set switch
Enables turn.on of LRU-1 high voltage power
OPR position
supply after 3-minute warm-up delay.
Applies dc power to LRU-1, but inhibits
STBY position
turn-on of high voltage power supply.
Removes all dc power from LRU-1
OFF position
When lit (green), indicates LRU-1 is in STBY
ON indicator
or OPR mode.
When lit (amber), indicates LRU-1 is in
STBY indicator
standby mode.
When lit (green), indicates LRU-1 is in
OPR indicator
operate mode.